home *** CD-ROM | disk | FTP | other *** search
/ TeX 1995 July / TeX CD-ROM July 1995 (Disc 1)(Walnut Creek)(1995).ISO / macros / text1 / cms_help_files / lir.helpmark < prev    next >
Text File  |  1991-10-23  |  2KB  |  47 lines

  1. +-----------------------------------------------------------------------------+
  2. |                                 listresume                                  |
  3. +-----------------------------------------------------------------------------+
  4.  
  5. Abbreviation:  π|\lirπ%
  6.  
  7. Parameters:    π|noneπ%
  8.  
  9.     π|Description:π%
  10. \listresume is used  to end a lower listlevel and  return to the next higher
  11. listlevel without starting a new point.
  12.  
  13.     π|Example:π%
  14. \lib
  15. \lil1 All fixed time controllers shall be equipped with
  16. indicating switches and wiring to provide local control
  17. of the following functions:
  18. \lil2 Transfer from automatic to manual operation,
  19. \lil2 Transfer from normal operation to flashing,
  20. \listresume
  21.  
  22. Combined master and intersection controllers shall have
  23. indicating switches for functions (b) and (c), above,
  24. for interconnected system.
  25. \par
  26. Combined master and intersection controllers shall also
  27. have provisions for time switch control.
  28. \lil1 All fixed-time controllers shall be  . . .
  29. \listend
  30.  
  31. +-----------------------------------------------------------------------------+
  32. |                                                                             |
  33. |   1. All fixed time controllers shall be equipped with indicating switches  |
  34. |      and wiring to provide local control of the following functions:        |
  35. |      a. Transfer from automatic to manual operation,                        |
  36. |      b. Transfer from normal operation to flashing,                         |
  37. |      Combined master  and intersection  controllers shall  have indicating  |
  38. |      switches for functions (b) and (c), above, for interconnected system.  |
  39. |          Combined  master and  intersection  controllers  shall also  have  |
  40. |      provisions for time switch control.                                    |
  41. |   2. All fixed-time controllers shall be  . . .                             |
  42. |                                                                             |
  43. +-----------------------------------------------------------------------------+
  44.  
  45.     π|Notes:π%
  46. none.
  47.